Part Number Hot Search : 
ST10F 2SC57 SP5668KG IW1770 CXOMK ATMEG ELJSC101 TDA98
Product Description
Full Text Search
 

To Download 70G-OAC5MA Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Manual Override Output Modules
FEATURES * Integral Three Position Manual On/Manual Off and Automatic Control Toggle Switch * Transient Protection: Meets the requirements of IEEE 472, "Surge Withstanding Capability Test" * UL, CSA Certified * Optical Isolation * G5 Modules Provide Replaceable 5x20 mm Glass Fuse * Built-in Status LED
CIRCUITRY
Maximum Current Versus Ambient Temperature The chart indicates continuous current to limit the junction temperatures to 100C. Information is based on steady state heat transfer in a two cubic foot sealed enclosure.
4
AC Outputs
+
1
DC Outputs
LOAD
1
LOAD VAC LOAD
SNUBBER
2
VDC
VOLTAGE SPIKE PROTECTION LOAD
2
-
TRIGGER CIRCUIT
LOAD CURRENT (AMPS)
G5 PACKAGE
DRIVER CIRCUIT
3 2
+
1
DC CONTROL
Rx
3 OFF 4 5
5
+
DC CONTROL
Rx
3 OFF 4 AUTO ON
-
-20 0 20 40 60 AMBIENT TEMPERATURE (C) 80 100
AUTO ON
-
-40
Figure 1 Maximum Peak Surge Current Versus Surge Duration (AC Outputs) Information is based on a supply frequency of 60 Hz sinusoidal and a resistive or inductive load. Application of maximum surge current may not be repeated until the module temperature has returned to its steady state value.
PEAK SURGE CURRENT (AMPERES)
300 200 100 80 60 40 30 20 10 6 4 3 1 1 1 1000 2 3 4 6 10 20 40 60 100 NUMBER OF FULL CYCLES AT 60 HERTZ
FUSES
G5 Fuses are 5 Amp Littelfuse part number 217005 or equivalent.
I/O Modules
I/O 12
STA NDA RD, MINI, G5
OPE
NLI
NE
Figure 2
Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois
60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com
Manual Override Output Modules
SPECIFICATIONS: All Modules*
Output Specifications
Load Current Range (rms): 0.03 to 3.5 Amps, Maximum current is derated as shown in Figure 1. Maximum Surge Current (peak): 80 Amps at 60 Hz, 1 cycle as qualified by Figure 2 for AC outputs. 5 Amp maximum for 1 second for DC outputs. Turn-on Time (60 Hz): 8.3 mSec maximum for AC outputs. 20 Sec maximum for DC outputs. Turn-off Time (60 Hz): 8.3 mSec maximum for AC outputs. 50 Sec maximum for DC outputs. ON State Voltage Drop (peak): 1.5 volts max. Power Dissipation: 1.0 Watt/Amp typical Mechanical Shock: 1500 G's 0.5 mS halfsine per MIL-STD-202, Method 213, Condition F Storage Temperature Range: -40C to +125C Operating Temperature Range: -40C to +100C
General Characteristics
Isolation Voltage Field to Logic: 4000 Vac (rms) minimum Vibration: 20 G's peak or .06" double amplitude 10-2000 Hz per MIL-STD-202, Method 204, Condition D
*Specifications apply over operating temperature range unless noted otherwise.
SPECIFICATIONS: By Part Number
AC Outputs
Type/Function G5, Zero Voltage Turn On, Manual Override Specifications Units 120 24-140 400 2 5 4-6 20 100 1 -5 8 25-70 240 24-280 600 4 5 4-6 20 100 1 -5 8 25-70 120 24-140 400 2 24 18-32 8 2700 1 -5 8 25-70 240 24-280 600 4 24 18-32 8 2700 1 -5 8 25-70 70G-OAC5MA Grayhill Part Number 70G-OAC5AMA 70G-OAC24MA 70G-OAC24AMA
Nominal Line Voltage Vac Load Voltage Range Vac Minimum Peak Blocking Voltage Volts Maximum Off-state Leakage @ 60Hz mA, rms Nominal Logic Voltage (Vcc) Vdc Logic Voltage Range Vdc Max. Logic Supply Current @ Nominal Vcc mA Nominal Input Resistance (Rx) Minimum Drop-Out Voltage Vdc Maximum Reverse Logic Voltage Vdc Maximum Zero Voltage Offset (Vpeak) Frequency Range (Hz)
DC Outputs
Type/Function G5 Manual Override Specifications Maximum Line Voltage Load Voltage Range Maximum Off-state Leakage @ 60 Vdc Maximum Turn-on Time Maximum Turn-off Time Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop-Out Voltage Maximum Reverse Logic Voltage Maximum Clamping Voltage Units Vdc Vdc mA Sec Sec Vdc Vdc mA Vdc Vdc Vdc 60 3-60 1.5 20 50 5 4-6 13 150 1 -5 80 60 3-60 1.5 20 50 24 18-32 9 2700 1 -5 80 Grayhill Part Number 70G-ODC5MA 70G-ODC24MA Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill.
I/O Modules
I/O 13
Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois
60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com


▲Up To Search▲   

 
Price & Availability of 70G-OAC5MA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X